Chromatography
Filtration
Liquid Handling
Sample Preparation
Water Quality Analyzer
Lab Product
Lab System
Environment Division
Agilent_PerkinElmer Spectroscopy

Pall > Membrane Filter
[60301] Supor(IC) 200 Membrane Disc Filter 0.2 um 47mm 100/pk
 
»óÇ°°¡°Ý °ßÀû¹®ÀÇ
±¸¸Å ÇýÅà Àû¸³±Ý1%
¸ðµ¨¸í WK60301
¿ø»êÁö ¹Ì±¹
Á¦Á¶»ç Pall(Çѱ¹Æú)
¹è¼Ûºñ ±âº» ¹è¼Û
¹è¼Û±â°£ 3ÀÏ ~ 30ÀÏ
¼ö·®
¼ö·®Áõ°¡ ¼ö·®°¨¼Ò
°ü½É»óÇ°
WK60301 / ºÎ°¡¼¼º°µµ


* ȯºÒ ½Ã °¡»ó°èÁ °áÁ¦º¸´Ù ¹«ÅëÀåÀÔ±Ý °áÁ¦ÀÇ È¯ºÒ ÀýÂ÷°¡ °£¼ÒÇÕ´Ï´Ù.

* ±³È¯ ¹× ¹ÝÇ°ÀÌ °¡´ÉÇÑ °æ¿ì
 - »óÇ° ¹è¼Û ¿Ï·á ÈÄ 7ÀÏ À̳»¿¡ ÇÑÇϸç, »óÇ°¿¡ ÇÏÀÚ°¡ Àְųª ÁÖ¹®ÇÑ »óÇ°°ú ´Ù¸¦ °æ¿ì 1:1 »óÇ°±³È¯ ¶Ç´Â Àü¾× ȯºÒ Á¶Ä¡ Çص帳´Ï´Ù.
 - »óÇ°¿¡ ÇÏÀÚ´Â ¾øÁö¸¸ ´Ù¸¥ »óÇ°À¸·Î ±³È¯Çϰųª ¹ÝÇ°À» ¿äû ÇÏ½Ç °æ¿ì, »õ »óÇ°ÀÎ °æ¿ì¿¡ ÇÑÇØ Á¶Ä¡ÇØ µå¸³´Ï´Ù.
   (´Ü, ÀÌ¿¡ ¼Ò¿äµÇ´Â ºñ¿ëÀº ±¸¸ÅÀÚ ºÎ´ã)
 - »óÇ°ÀÌ ÆÐÅ·µÈ ºñ´Ò ¹× ¹Ú½º°¡ ¼ö·ÉÇϽŠ±×´ë·Î º¸Á¸ÇÏ°í ÀÖÀ» °æ¿ì¿¡¸¸ Á¶Ä¡ Çص帳´Ï´Ù.

* ±³È¯ ¹× ¹ÝÇ°ÀÌ ºÒ°¡´ÉÇÑ °æ¿ì
1. »óÇ°ÀÇ Æ÷ÀåÀ» ÈÑ¼Õ ÇÑ °æ¿ì
2. »óÇ°ÀÌ ÈÑ¼ÕµÇ¾î »óÇ°°¡Ä¡°¡ ÇöÀúÈ÷ »ó½ÇµÇ°í, ÀçÆǸŰ¡ ºÒ°¡´ÉÇÑ °æ¿ì
3. Àç°í »óÇ°ÀÌ ¾Æ´Ñ °æ¿ì¿¡ ¼öÀÔ ¹ßÁÖ µÇ¾îÁø »óÇ°ÀÏ °æ¿ì
4. °í°´ÀÇ ¿äûÀ¸·Î ÁÖ¹® Á¦ÀÛµÈ »óÇ°ÀÏ °æ¿ì


¢ºÈ¸¿ø µî±Þº° ÇýÅú¸±â[»õâ]

detail prdoduct - »óÇ°»ó¼¼¼³¸í


High Flow Rate Membrane Optimized for Biological, Pharmaceutical, and Sterilizing Filtration Requirements
 - Fast filtration with superior flow rates and high throughputs 
 - Low protein binding and extensive drug compatibility for critical applications
 - Saves time and money with fewer filter changes per sample volume
 - 142 and 293 mm discs feature printed tab for instant recognition of pore size and lot number
 - May be sterilized by gamma irradiation, EtO, or autoclaving


 



 


Specification





Filter Media
 - Hydrophilic polyethersulfone (PES)


Pore Size
 - 0.1, 0.2, 0.45, and 0.8 ¥ìm


Diameter
 - 13 - 293 mm


Typical Thickness
 - 0.1 ¥ìm: 132 ¥ìm (5.2 mils)
 - 0.2 ¥ìm: 145 ¥ìm (5.7 mils)
 - 0.45 and 0.8 ¥ìm: 140 ¥ìm (5.5 mils)


Typical Water Flow Rate
 - mL/min/cm2 at 0.7 bar (70 kPa, 10 psi)
   0.1 ¥ìm: 5
   0.2 ¥ìm: 26
   0.45 ¥ìm: 58
   0.8 ¥ìm: 165


Maximum Operating Temperature - Water
 - 100 ¡ÆC (212 ¡ÆF)


Extractables - Soxhlet Extraction
 - < 4%


Minimum Bubble Point - Water
 - 0.2 ¥ìm: 3.5 bar (350 kPa, 51 psi)
 - 0.45 ¥ìm: 2.5 bar (250 kPa, 36 psi)
 - 0.8 ¥ìm: 1.0 bar (100 kPa, 15 psi)


60% IPA/40% H2O (v:v)
 - 0.1 ¥ìm: 2.4 bar (240 kPa, 35 psi)


Biological Safety
 - Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88>


Sterilization
 - Provided non-sterile. Can be sterilized by autoclaving at 121 - 123 ¡ÆC (250 - 253 ¡ÆF) for 30 min.


   PN 63025, 60043, 65472, 5010, and 66234 are provided gamma-irradiated.

relation product - °ü·Ã»óÇ°

review board - »óÇ°Èıâ Àüüº¸±â

review ÀÛ¼º Æû
review board
ÀÌ ¸§ :
ÆòÁ¡ :      
³» ¿ë :
Èı⾲±â
review ¸®½ºÆ®
À̸§
³»¿ë
ÆòÁ¡
³¯Â¥

QnA board - »óÇ°¹®ÀÇ

QnA ¸®½ºÆ®
µî·ÏµÈ ¹®ÀÇ°¡ ¾ø½À´Ï´Ù.

Item size chart »çÀÌÁî ±âÁØÇ¥

* »óÇ°»çÀÌÁî Ä¡¼ö´Â Àç´Â ¹æ¹ý°ú À§Ä¡¿¡ µû¶ó 1~3cm ¿ÀÂ÷°¡ ÀÖÀ» ¼ö ÀÖ½À´Ï´Ù.

ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â